Air compressor safety operation specification
Observe the general rules for the safe operation of pressure vessels:
Check all protective devices and safety accessories before driving to check that the lubricating oil surface is in compliance with the standard. Do not drive without permission.
The internal and external inspection of gas storage tanks and conduit joints shall be conducted once a year, all periodic inspections and hydraulic strength tests shall be conducted every three years, and detailed records shall be made, and the working pressure shall be indicated on the gas storage tanks, the date of the next inspection, and professional The inspection unit shall issue a “confirmation certificateâ€, and the gas storage tank that has not passed the inspection shall not be used.
The safety valve shall be pressed according to the working pressure, and each shift shall be pulled and inspected once. The automatic start test shall be performed once a week and the standard pressure gauge shall be calibrated once every six months, and the seal shall be added.
When inspecting and repairing, care should be taken to prevent wood chips, iron filings, wipes, etc. from falling into cylinders, gas storage tanks and conduits.
The parts cleaned with diesel must be operated without load for 10 minutes, and no abnormalities can be put into normal operation.
No repair work shall be carried out while the machine is in operation or under pressure from the equipment.
The pressure gauge should be verified, sealed and kept in good condition every year. If the pointer is not returned to the zero position during use, the dial scale is unclear or broken, etc., it should be replaced immediately. If abnormal sound, odor, vibration or malfunction occurs during operation during operation, stop immediately and use it after inspection.
The water-cooled air compressor first cools the water valve before driving, and then turns on the motor. When there is no cooling water or water stop, stop running. In the case of high-voltage motors, contact the power distribution room before starting and follow the relevant electrical safety procedures.
Non-machine room operators are not allowed to enter the machine room, because the work needs, must be approved by the relevant departments. No flammable or explosive materials are allowed in the equipment room.
Concerned about surprises