What should I do if the axial piston pump fails?

In the above, we have analyzed the main performance of the axial piston pump failure. In this paper, Dalan Motor Xiaobian will give a solution to these faults. For your reference only.
In the above, we have analyzed the main performance of the axial piston pump failure. In this paper, Dalan Motor Xiaobian will give a solution to these faults. For your reference only.

Fault 1: insufficient traffic

1 Check the oil storage capacity, refuel to the oil standard line, remove the oil pipe blockage, clean the oil filter, tighten the connecting screws to eliminate air leakage;

2 Exclude the air inside the pump;

3 replace the center spring;

4 flatten the contact surface of the oil pan and the cylinder with a single cylinder to replace the plunger;

5 When the low pressure is used, the variable piston and the variable head are freely movable; when the pressure is high, the adjustment error is corrected;

6 Select the appropriate oil according to the temperature rise.

Fault 2: Pressure pulsation

1 Smoothing the contact surface between the oil pan and the cylinder block, researching the single cylinder, replacing the plunger, tightening the screws at each joint to eliminate leakage;

2 appropriately increase the deviation angle of the variable mechanism to eliminate internal leakage;

3 Occasionally pulsating, mostly due to oily dirt, can be replaced with new oil, often pulsating, may be a joint injury or sturdy, should be removed for research;

4 Unblock the inlet pipe and clean the inlet oil filter, and tighten the connecting Screw of the inlet pipe section.

Fault 3: Noise

1exclude the air inside the pump;

2 Add sufficient oil according to the regulations, dredge the oil inlet pipe, clean the oil filter, and tighten the connecting screw of the oil inlet section;

3 Re-adjust to make the hydraulic motor concentric with the pump.

Fault 4: fever

1 repairing each sealing mating surface;

2 repair or replace worn parts;

Fault 5: Leakage

1 Check the sealing ring and each sealing part to eliminate the internal leakage;

2 Replace the O-ring;

3 smoothing the contact surface, matching the cylinder block, single-fitted to the plug;

4 Replace when severe.

Fault 6: The pump cannot be turned (killed)

1 When the oil is dirty, replace the new oil. When the oil temperature is too low, replace the mechanical oil with less viscosity;

2 replace or reassemble the shoe;

3 Replace the parts.







----- Editor-in-Chief: Dalan Oil Pump Motor 02-Procurement Consultant